GENERAL INFORMATION
The Dicon 440 SRIM photoelectric (optical) smoke alarm use aproven concept, the scattered light principle, to "see" smoke within the alarm chamber.
NOW UPGRADED to the 441SRIM with enhanced optical sensor
A regulated pulse of infrared light from a light emitting diode (LED) is introduced into a darkened smoke alarm chamber approximately every ten seconds to form a precise beam. When smoke enters this chamber, it interferes with the beam and scatters the light. The amount of light scattered within the chamber is monitored by a
strategically placed photodiode. When a predetermined level of light strikes the photodiode, the alarm is activated.
The unique smoke chamber design virtually eliminates ambient tight interference in a normal home environment, but still allows easy access for smoke particles from all sides and results in an extremely sensitive and stable smoke alarm.


TECHNICAL SPECIFICATION

Sensor: Photoelectric
Alarm Sound Level: 85dB (A) at 3 metres
Operating Voltage: 12-28 Volts DC
Standby Current: 10 mA
Alarm Current: 80 mA
Test Button: Tests sensitivity, circuitry and sounder
Interconnection: Maximum 12 alarms
Temperature Range: 5*C to 39*C
Humidity Range: 10% to 85% Relative Humidity
Dimensions: Diameter 155 mm, Height: 38mm
16.80
OUT OF STOCK
BRK DICON 650M Mains Powered Interconnectable Photoelectric Smoke AlarmNo Battery Backup

Production DescriptionThe 650M is a 230V mains powered optical smoke alarm. Up to 12 mains powered smoke and heat alarms can be linked for simultaneous warning. Features
  • 230 Volt Mains Powered
  • Test and alarm pause button
  • Multi-Alarm Interlink
  • LED Operating Indicators
  • Alarm Source Indicator
  • Mounting Base Plate
  • Low-profile design
  • 5 Year Guarantee
  • Certified to BS EN 14604: 2005
  • Dimensions: 133mm dia x 38mm

Download or view Data Sheet

20.61
BRK DICON 650MBX (660MBX) Mains Powered Interconnectable Photoelectric Smoke AlarmWith Alkaline Battery Backup

The Dicon 650MBX Mains Photoelectric Smoke Alarm incorporates the latest technology for seeing visible particles of combustion, making it ideal for detecting slow, smouldering fires.
The 9 volt battery back up provides power to the unit in the event of a mains failure.
Up to 12 compatible smoke and heat alarms can be linked for simultaneous warning.

Features
  • 230 Volt Mains Powered
  • 9V Battery Included
  • Test Button
  • Low Battery Warning
  • Superior Sensing Technology
  • Multi-Alarm Interlink
  • LED Operating Indicators
  • Alarm Source Indicator
  • Sensitivity Test Button
  • Mounting Base Plate
  • Push-fit Connector - Easy to Install
  • 5 Year Guarantee
  • Certified to BS EN 14604: 2005
  • CE
  • Dimensions: 133mm dia x 38mm
Technical Specifications

Sensor..........................Photoelectric
Voltage.........................230 volt AC (~) 50-60Hz
Back up........................9V PP3 battery back up
Interlink.........................Up to 12 alarms
Alarm Sound Level........85dB at 3m
Indicator Light...............Solid-state LEDs AC power green; circuitry & backup red
Operating Temp Range......5C (40F) to 38C (100F)
Relative Humidity..........10% to 85%
Dimensions...................133mm x 38mm
Weight..........................135g
Test & Pause Button.....Tests sensitivity, circuits, horn.

Download or view Data Sheet
24.74
Discontinued Product
BRK DICON 650MC Mains Powered Interconnectable Photoelectric Smoke Alarmwith Capacitor Backup

Uncompromisingly designed with public sector development in mind the Dicon 650MC 230 volt Hardwire Smoke Alarm is a mains powered photoelectric device; incorporating the latest technology for seeing visible particles of combustion, making it ideal for detecting slow smouldering fires.

The environment-friendly capacitor back up provides power to the unit in the event of a mains failure for a minimum of 72 hours in standby mode.
Up to 12 suitable smoke and heat alarms can be linked for simultaneous warning.
With capacitor back up there is no need to replace batteries.
Features
  • 230 Volt Mains Powered
  • No batteries required
  • Tamper Proof Capacitor Back up
  • Photoelectric - Most Sensitive to Smouldering Fires
  • Superior Sensing Technology
  • Multi-Alarm Interlink
  • LED Operating Indicators
  • Alarm Source Indicator
  • Full Integral Capacitor Monitoring
  • Mounting Base Plate
  • Push-fit Connector - Easy to Install
  • 5 Year Guarantee
  • Certified to BS EN 14604: 2005
  • CE
  • Dimensions: 133 mm dia x 38 mm
Technical Specifications

Sensor..........................Photoelectric
Voltage.........................230 volt AC (~) 50-60Hz
Capacitor Back up........Minimum 72 hours standby plus 4 minutes alarm
Interlink.........................Up to 12 alarms
Alarm Sound Level........85dB at 3m
Indicator Light...............Solid-state LEDs AC power green; circuitry red
Operating Temperature Range......5C (40F) to 38C (100F)
Relative Humidity..........10% to 85%
Dimensions...................133mm x 38mm
Weight..........................170g
Test & Pause Button.....Tests sensitivity, circuits, horn.


Download or view Data Sheet