BRK COMPATIBILITY PLEASE NOTE THAT ALL BRK ALARMS USE THE SAME ELECTRICAL CONNECTOR & ARE COMPATIBLE WITH ALL OTHER MODELS OF BRK ALARMS BOTH PAST & PRESENT
BRK COMPATIBILITY PLEASE NOTE THAT ALL BRK ALARMS USE THE SAME ELECTRICAL CONNECTOR & ARE COMPATIBLE WITH ALL OTHER MODELS OF BRK ALARMS BOTH PAST & PRESENT
Ionisation or Photoelectric (Optical)? While all smoke alarms are designed to detect smoke, certain sensing technologies react differently to certain types of fire.Photoelectric sensing technology is generally more sensitive (than ionization sensing technology) at detecting large particles. Large particles tend to be produced in greater amounts by shouldering fires. These fires may smoulder for hours before bursting into flames.
Ionization sensing technology is generally more sensitive (than photoelectric sensing technology) at detecting small particles. Small particles tend to be produced in greater amounts by flaming fires. These fires consume combustible materials rapidly and spread quickly.
For optimum protection we recommend the use of both photoelectric and ionization alarms on each level of a house.
BRK COMPATIBILITY PLEASE NOTE THAT ALL BRK ALARMS USE THE SAME ELECTRICAL CONNECTOR & ARE COMPATIBLE WITH ALL OTHER MODELS OF BRK ALARMS BOTH PAST & PRESENT
BRK 6230BFP Mains Powered Interconnectable Heat Alarm With Alkaline Battery Back Up PLEASE NOTE THAT THIS HEAT ALARM HAS BEEN REPLACED BY THE DICON 680MBX - SEE BELOW BRK’s Heat Alarms have been developed for use in places where a smoke detector may not be suitable. A Heat Alarm gives additional fire warning protection when used in conjunction with a smoke detector system. BRK’s Heat Alarms can be used in areas where high ambient air temperatures, high humidity, condensation or cooking may cause a smoke detector to be activated falsely. Ideally Heat Alarms should be used in all kitchen-diners, lofts, garages or boiler rooms. Building Regulations recognise the importance of Heat Alarms and recommend them to be installed in addition to or as an alternative when smoke alarms are unsuitable. Heat Alarms could also be considered for integral garages connected to the house via a door. Flammable liquids inside a garage or workshop can be a distinct fire risk and the typically dusty atmosphere would not be a suitable environment for a smoke detector. BRK’s Heat Alarms should not be used as a replacement for smoke alarms, but can be used in conjunction with or as stand alone fire detection. BRK’s smoke and heat alarms can be fully integrated into BRK’s Flexipoint mini-system.
LARGER IMAGE & DESIGN AND INSTALLATION INFORMATION
Price: £30.45 £35.78 Including VAT at 17.5%
BRK COMPATIBILITY PLEASE NOTE THAT ALL BRK ALARMS USE THE SAME ELECTRICAL CONNECTOR & ARE COMPATIBLE WITH ALL OTHER MODELS OF BRK ALARMS BOTH PAST & PRESENT
Dicon 680MBX Mains Powered Heat Alarm with Alkaline Battery Backup The Dicon 680MBX 230 volt Heat Alarm with battery back up is designed for use in the kitchen, garage and boiler room. Incorporating a thermistor heat sensing element for accuracy and reliability, the 680MBX can be linked to up to 11 compatible mains smoke and heat alarms, providing additional protection.Features
BRK Electronics 2002 RACEN (RACE) Mains Powered Interconnectable Photoelectric Smoke Alarm PLEASE NOTE THAT THIS ALARM HAS NOW BEEN SUPERSEDED. Two Options Available:
Option 1 Replace with BRK 86RACEN - this will fit both your existing ceiling pattress (if fitted) and electrical connector. Please note - the 86RACEN uses an ionisation sensor.
Or
Option 2 Replace with same type of sensor - i.e. Phototelectric - by using the BRK 7010BE. This alarm has a smaller base diameter 131mm (as opposed to 145mm for the 2002) and will need the new ceiling plate (supplied) fitting in place of the existing ceiling plate and if there is a pattress (junction box base) fitted onto the ceiling, the new 7010BE plate will need to be screwed to the existing ceiling plate.
TO PURCHASE EITHER OF THESE REPLACEMENT ALARMS - SEE ABOVE
CLICK HERE TO SEE HOW THE NEW 7010 CAN BE INSTALLED ONTO YOUR EXISTING CEILING PLATE
Larger Image...
BRK 2002RACHE10N Mains Powered Interconnectable Photoelectric Smoke Alarm PLEASE NOTE THAT THIS ALARM HAS NOW BEEN SUPERSEDED Two Options Available:
Option 1 Replace with BRK 86RACHE10N - this will fit both your existing ceiling pattress (if fitted) and electrical connector. Please note - the 86RACHE10N uses an ionisation sensor.
Or
Option 2 Replace with same type of sensor - i.e. Phototelectric - by using the BRK 7010LBE. This alarm has a smaller base diameter 131mm (as opposed to 145mm for the 2002) and will need the new ceiling plate (supplied) fitting in place of the existing ceiling plate and if there is a pattress (junction box base) fitted onto the ceiling, the new 7010BE plate will need to be screwed to the existing ceiling plate.
TO PURCHASE EITHER OF THESE REPLACEMENT ALARMS - SEE ABOVE
CLICK HERE TO SEE HOW THE NEW 7010 CAN BE INSTALLED ONTO YOUR EXISTING CEILING PLATE